FT6(FZW3A)-12 Outdoor

FT6-12 can be used in outdoor three-phase AC power system of rated voltage 10 (12) kV and rated frequency 50HZ for opening and closing load current, non-load line and non-load transformer.

Features :

  • Vertical rotating structure is used for this kind of product, which can avoid the risk of closing automatically.
  • Vacuum arc-extinguished compartment is equipped in the fully sealed enclosure that operated by high-speed mechanism, and will be not influenced by the outside operation and environment. It can do arc extinguish safety and reliably.
  • The safety of operation is improved by the connection of vacuum arc-chute and isolating control with no possibility of mis-operation. It has obvious fracture that meets the requirements of disconnecting protection. 
  • The material of the exposed components is made of stainless steel, and has long life service. 
  • The characteristics of the switchgear are neat structure, small volume, less weight and simple, reliable mechanism. It can be operated by two methods: manual operation or dual-purpose operation that is manual or electric. It can be used in the automation of network or the operation of sectional device.

The weight of load switchgear: manual or electric operation <=65kg, manual operation<=55kg.

Technical Parameter

No

Item

Unit

Parameter

1

Rated voltage

KV

12

2

Rated frequency

Hz

50

3

Rated current

A

630

4

Rated active load breaking current

A

630

5

Rated closed loop breaking current

A

630

6

5% rated active load breaking current

A

31.5

7

Rated charging breaking current of cable

A

10

8

Rated breaking current of no-load transformer

A

Non-load current of 6000kVA transformer

9

Rated short-time withstand current

KA/s

16/4

10

Rated breaking current of the condenser

A

400

11

Rated peak withstand current

KA

40

12

Rated short-circuit making current

KA

40

13

Rated 1min power frequency withstand voltage (r.m.s) phase to earth, phase-to-phase, vacuum fracture/isolated fracture

KV

42/48

14

Lightning impulse withstand voltage (crest) phase to earth, phase-to-phase, vacuum fracture/isolated fracture

KV

75/85

15

1min wet, withstand voltage earth to earth, phase to phase, isolating point

KV

30/34

16

1min power frequency withstand voltage for isolating point of arc-extinguished compartment

KV

20

17

Mechanical Endurance

Times

2000


Please indicate while ordering:

  • a. The type, name and quantity;
  • b. The installation position, top bar or several meters below the top bar and diameter of bar;
  • c. Operative methods: manual operation or dual-purpose operation that is manual or electric;
  • d. Please keep contact with us , if you have special order.

You can ask Data Sheet List for this product before order by e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.or This email address is being protected from spambots. You need JavaScript enabled to view it.

More in this category: FZRN21-40.5 Indoor »